{"title":"Grease Arrestors","description":"\u003cp\u003eCommercial \u003cstrong\u003egrease arrestors and grease traps\u003c\/strong\u003e for cafes, restaurants, canteens, hospitals, bars and hotels. Designed to separate fats, oils, grease and suspended solids from trade waste before it reaches the sewer, and to meet local water authority pre-treatment requirements.\u003c\/p\u003e\u003cp\u003eAvailable in polyethylene and fibre-reinforced polymer, in sizes from 1000L to 2000L, rated for both above ground and below ground installation.\u003c\/p\u003e","products":[{"product_id":"kwikflo-kgt1000-1000l-grease-trap-arrestor-above-below-ground","title":"Kwikflo KGT1000 1000L Grease Trap Arrestor - Above \u0026 Below Ground","description":"\u003cp\u003eThe Kwikflo KGT1000 Grease Arrestor is a 1000L polyethylene grease trap built to remove fats, oils, grease and suspended solids from commercial kitchen wastewater before it reaches the sewer. It suits above ground and below ground installation, making it a practical fit for cafés, restaurants, canteens, hospitals, bars and hotels that need a certified pre-treatment stage. Manufactured by Aline Pumps, the Kwikflo range is an approved listed pre-treatment product for food businesses.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRemoves fats, oils, grease and suspended solids from trade waste\u003c\/li\u003e\n\u003cli\u003e1000L polyethylene tank, model KGT1000\u003c\/li\u003e\n\u003cli\u003eSuitable for both above ground and below ground installation\u003c\/li\u003e\n\u003cli\u003eApproved listed pre-treatment for food businesses\u003c\/li\u003e\n\u003cli\u003eInternal pipework directs flow to the base of the tank to avoid re-suspending settled sludge\u003c\/li\u003e\n\u003cli\u003e600mm square manhole for access and servicing\u003c\/li\u003e\n\u003cli\u003eWide range of lid options from Class B through to Class D load ratings\u003c\/li\u003e\n\u003cli\u003eRisers available on request for deeper below-ground installs\u003c\/li\u003e\n\u003cli\u003eHandles raw sewage, trade waste, effluent and stormwater\u003c\/li\u003e\n\u003cli\u003eCompact 2060mm x 710mm footprint\u003c\/li\u003e\n\u003cli\u003ePart of the Kwikflo range spanning 1000L to 5000L, with custom fibreglass sizes available\u003c\/li\u003e\n\u003cli\u003eCan be configured in dual inline or dual parallel arrangements for higher flows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kgt1000-feature.png?v=1784357563\" alt=\"Kwikflo KGT1000 1000L Grease Arrestor features and specifications\"\u003e\u003c\/p\u003e\n\u003ch2\u003eProven Grease Separation for Commercial Kitchens\u003c\/h2\u003e\n\u003cp\u003eCommercial kitchens push a constant load of fats, oils and grease into their drainage. Left untreated, that material cools and hardens in the sewer line, which is why water authorities require food businesses to install a grease arrestor as a pre-treatment stage.\u003c\/p\u003e\n\u003cp\u003eThe KGT1000 gives cafés, restaurants and institutional kitchens a 1000L holding volume where that separation happens under gravity, before the wastewater is discharged to sewer.\u003c\/p\u003e\n\u003ch2\u003eInternal Pipework That Protects the Settled Layers\u003c\/h2\u003e\n\u003cp\u003eContaminated water arrives through the inlet pipe and is directed by the internal pipework down to the base of the tank.\u003c\/p\u003e\n\u003cp\u003eFeeding the flow low into the tank avoids stirring up sludge and grease that has already separated. Without this, incoming water would mix the tank contents and carry separated material back toward the outlet.\u003c\/p\u003e\n\u003cp\u003eInside the tank, the wastewater slows and separates into three layers. Sludge and heavier solids settle into the base of the unit, grease is trapped and floats to the surface, and the treated liquid in the middle is discharged from the grease arrestor to sewer.\u003c\/p\u003e\n\u003ch2\u003eAbove Ground or Below Ground Installation\u003c\/h2\u003e\n\u003cp\u003eThe KGT1000 is rated for both above ground and below ground installation, so it can sit in a plant room, service yard, or be buried under a trafficable area with the appropriate lid.\u003c\/p\u003e\n\u003cp\u003eFor sites with higher flows than a single 1000L unit can handle, the Kwikflo range supports dual parallel and dual inline configurations, and steps up through 1500L poly to 2000L, 3000L, 4000L and 5000L fibre-reinforced polymer models.\u003c\/p\u003e\n\u003ch2\u003eStraightforward Servicing Access\u003c\/h2\u003e\n\u003cp\u003eA 600mm square manhole gives access for pump-out and inspection. Grease arrestors need regular pump-out by a licensed liquid waste contractor, at a frequency set by the local water authority based on the size of the unit and the kitchen's output.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGravity grease separation\u003c\/li\u003e\n\u003cli\u003eRemoves fats, oils and grease\u003c\/li\u003e\n\u003cli\u003eRemoves suspended solids\u003c\/li\u003e\n\u003cli\u003e1000L nominal volume\u003c\/li\u003e\n\u003cli\u003eInternal pipework directed to the base of the tank\u003c\/li\u003e\n\u003cli\u003eAvoids re-suspension of settled sludge and grease\u003c\/li\u003e\n\u003cli\u003eSludge and solids settle into the base of the unit\u003c\/li\u003e\n\u003cli\u003eGrease trapped and floated to the surface\u003c\/li\u003e\n\u003cli\u003eTreated liquid discharged to sewer\u003c\/li\u003e\n\u003cli\u003ePolyethylene tank construction\u003c\/li\u003e\n\u003cli\u003e600mm square manhole\u003c\/li\u003e\n\u003cli\u003eAbove ground installation\u003c\/li\u003e\n\u003cli\u003eBelow ground installation\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003cli\u003eMultiple lid options across Class B and Class D ratings\u003c\/li\u003e\n\u003cli\u003eDual inline configuration capability\u003c\/li\u003e\n\u003cli\u003eDual parallel configuration capability\u003c\/li\u003e\n\u003cli\u003eApproved listed pre-treatment for food businesses\u003c\/li\u003e\n\u003cli\u003ePart of a range extending from 1000L to 5000L\u003c\/li\u003e\n\u003cli\u003eCustom fibreglass sizes available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConstruction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePolyethylene (poly) grease arrestor tank\u003c\/li\u003e\n\u003cli\u003e1000L volume\u003c\/li\u003e\n\u003cli\u003e2060mm length\u003c\/li\u003e\n\u003cli\u003e710mm width\u003c\/li\u003e\n\u003cli\u003e1485mm depth\u003c\/li\u003e\n\u003cli\u003e600mm square manhole\u003c\/li\u003e\n\u003cli\u003eInternal inlet pipework directed to the base of the tank\u003c\/li\u003e\n\u003cli\u003eInlet and outlet connections on opposite ends of the tank\u003c\/li\u003e\n\u003cli\u003eMoulded external ribbing for structural strength\u003c\/li\u003e\n\u003cli\u003eInlet plumbing to be installed by a licensed plumber\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003cli\u003eLid selected separately to suit the installation and load class\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLiquids Handled\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRaw sewage\u003c\/li\u003e\n\u003cli\u003eTrade waste\u003c\/li\u003e\n\u003cli\u003eEffluent\u003c\/li\u003e\n\u003cli\u003eStormwater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCafés\u003c\/li\u003e\n\u003cli\u003eRestaurants\u003c\/li\u003e\n\u003cli\u003eCanteens\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eBars and hotels\u003c\/li\u003e\n\u003cli\u003eCommercial kitchens\u003c\/li\u003e\n\u003cli\u003eFood business trade waste pre-treatment\u003c\/li\u003e\n\u003cli\u003eAbove ground grease arrestor installations\u003c\/li\u003e\n\u003cli\u003eBelow ground grease arrestor installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eContaminated water arrives through the inlet pipe.\u003c\/p\u003e\n\u003cp\u003eThe internal pipework directs that flow to the base of the tank, which avoids mixing and re-suspending sludge and grease that has already settled or risen.\u003c\/p\u003e\n\u003cp\u003eSludge and solids settle in the base of the unit.\u003c\/p\u003e\n\u003cp\u003eGrease is trapped and floats to the surface.\u003c\/p\u003e\n\u003cp\u003eTreated liquid is discharged from the grease arrestor to sewer.\u003c\/p\u003e\n\u003ch2\u003eInstallation Information\u003c\/h2\u003e\n\u003cp\u003eThe KGT1000 can be installed above ground or below ground. Inlet plumbing is to be installed by a licensed plumber, and risers are available on request where the tank sits deeper below finished surface level.\u003c\/p\u003e\n\u003cp\u003eImportant installation considerations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe water level and outlet pipe must sit 150mm below the inlet.\u003c\/li\u003e\n\u003cli\u003eThe inlet connections are on one end of the tank and the outlet connections on the opposite end.\u003c\/li\u003e\n\u003cli\u003eThe lid must be selected to match the installation type and the traffic load passing over it.\u003c\/li\u003e\n\u003cli\u003eBelow ground installations require a load-rated cover, with Class B and Class D options available.\u003c\/li\u003e\n\u003cli\u003eAbove ground installations can use the poly or fibreglass 600x600 lid, or the 200mm poly inspection port lid.\u003c\/li\u003e\n\u003cli\u003eSites with flows beyond a single 1000L unit may require a dual parallel or dual inline arrangement.\u003c\/li\u003e\n\u003cli\u003eSizing, trade waste approval and pump-out frequency are set by the local water authority.\u003c\/li\u003e\n\u003cli\u003eFinal sizing and installation should be approved by the relevant hydraulic consultant, engineer, licensed plumber and local authority.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eKGT1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGrease Arrestor \/ Grease Trap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e1000L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e2060mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e710mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e1485mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManhole\u003c\/td\u003e\n\u003ctd\u003e600mm Square\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (Poly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eAbove and Below Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparation Method\u003c\/td\u003e\n\u003ctd\u003eGravity Separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparated Materials\u003c\/td\u003e\n\u003ctd\u003eFats, Oils, Grease and Suspended Solids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquids Handled\u003c\/td\u003e\n\u003ctd\u003eRaw Sewage, Trade Waste, Effluent and Stormwater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Level Requirement\u003c\/td\u003e\n\u003ctd\u003e150mm Below the Inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisers\u003c\/td\u003e\n\u003ctd\u003eAvailable on Request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Plumbing\u003c\/td\u003e\n\u003ctd\u003eTo Be Installed by Plumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eListed Pre-Treatment for Food Businesses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Reference\u003c\/td\u003e\n\u003ctd\u003eMPT\/AGA\/1000L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAline Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eKwikflo Grease Trap Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eExact dimensions, nominal operating volume, lid selection and riser requirements for the KGT1000 should be confirmed against the current manufacturer's technical drawing before ordering.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Kwikflo KGT1000 1000L Polyethylene Grease Arrestor Tank\u003c\/li\u003e\n\u003cli\u003e1 x Set of Internal Inlet Pipework Directed to the Base of the Tank\u003c\/li\u003e\n\u003cli\u003e1 x 600mm Square Manhole Opening\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLids, risers and inlet plumbing are selected and supplied separately to suit the installation. Contact our team to specify the correct lid class and riser configuration for your site.\u003c\/p\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kwikflo-kgt1000-1000l-grease-arrestor-brochure.pdf?v=1784358230\"\u003eProduct Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eNeed Assistance or Ready to Order?\u003c\/h2\u003e\n\u003cp\u003eOur expert team is here to help you select the perfect setup and answer any questions. Contact us at sales@waternex.com.au or give us a call at 1300 930 847 for personalized advice and support.\u003c\/p\u003e","brand":"Kwikflow","offers":[{"title":"Default Title","offer_id":55349190918435,"sku":"KGT1000","price":2999.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kgt1000-hero.png?v=1784357560"},{"product_id":"kwikflo-kgt1500-1500l-grease-trap-arrestor-above-below-ground","title":"Kwikflo KGT1500 1500L Grease Trap Arrestor - Above \u0026 Below Ground","description":"\u003cp\u003eThe Kwikflo KGT1500 Grease Arrestor is a 1500L polyethylene grease trap built to remove fats, oils, grease and suspended solids from commercial kitchen wastewater before it reaches the sewer. The extra 500L over the 1000L model suits busier kitchens and longer service periods between pump-outs. It is rated for above ground and below ground installation and is an approved listed pre-treatment product for food businesses, manufactured by Aline Pumps.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRemoves fats, oils, grease and suspended solids from trade waste\u003c\/li\u003e\n\u003cli\u003e1500L polyethylene tank, model KGT1500\u003c\/li\u003e\n\u003cli\u003eSuitable for both above ground and below ground installation\u003c\/li\u003e\n\u003cli\u003eApproved listed pre-treatment for food businesses under MPT\/AGA\/1500L\u003c\/li\u003e\n\u003cli\u003eInternal pipework directs flow to the base of the tank to avoid re-suspending settled sludge\u003c\/li\u003e\n\u003cli\u003e600mm square manhole for access and servicing\u003c\/li\u003e\n\u003cli\u003eLonger interval between pump-outs than a 1000L unit at the same kitchen load\u003c\/li\u003e\n\u003cli\u003eRisers available on request for deeper below-ground installs\u003c\/li\u003e\n\u003cli\u003eHandles raw sewage, trade waste, effluent and stormwater\u003c\/li\u003e\n\u003cli\u003e2925mm x 710mm footprint, same width and depth as the 1000L model\u003c\/li\u003e\n\u003cli\u003eCan be configured in dual inline arrangements for higher flows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kgt1500-feature.png?v=1784359177\" alt=\"Kwikflo KGT1500 1500L Grease Arrestor features and specifications\"\u003e\u003c\/p\u003e\n\u003ch2\u003eMore Capacity for Busier Kitchens\u003c\/h2\u003e\n\u003cp\u003eCommercial kitchens push a constant load of fats, oils and grease into their drainage. Left untreated, that material cools and hardens in the sewer line, which is why water authorities require food businesses to install a grease arrestor as a pre-treatment stage.\u003c\/p\u003e\n\u003cp\u003eThe KGT1500 holds 1500L, giving a longer retention time and more room for accumulated grease and sludge than a 1000L unit at the same kitchen load. For sites where the local water authority has set a pump-out frequency that a smaller tank cannot meet comfortably, the extra volume is usually the deciding factor.\u003c\/p\u003e\n\u003cp\u003eIt shares the 710mm width and 1485mm depth of the 1000L model and gains its capacity in length, at 2925mm, which often makes it a straight swap where width is constrained.\u003c\/p\u003e\n\u003ch2\u003eInternal Pipework That Protects the Settled Layers\u003c\/h2\u003e\n\u003cp\u003eContaminated water arrives through the inlet pipe and is directed by the internal pipework down to the base of the tank.\u003c\/p\u003e\n\u003cp\u003eFeeding the flow low into the tank avoids stirring up sludge and grease that has already separated. Without this, incoming water would mix the tank contents and carry separated material back toward the outlet.\u003c\/p\u003e\n\u003cp\u003eInside the tank, the wastewater slows and separates into three layers. Sludge and heavier solids settle into the base of the unit, grease is trapped and floats to the surface, and the treated liquid in the middle is discharged from the grease arrestor to sewer.\u003c\/p\u003e\n\u003ch2\u003eAbove Ground or Below Ground Installation\u003c\/h2\u003e\n\u003cp\u003eThe KGT1500 is rated for both above ground and below ground installation, so it can sit in a plant room, service yard, or be buried under a trafficable area with the appropriate lid.\u003c\/p\u003e\n\u003cp\u003eWhere a single 1500L unit is not enough, the Kwikflo range supports dual inline and dual parallel configurations, and steps up to fibre-reinforced polymer models at 2000L and above.\u003c\/p\u003e\n\u003ch2\u003eStraightforward Servicing Access\u003c\/h2\u003e\n\u003cp\u003eA 600mm square manhole gives access for pump-out and inspection. Grease arrestors need regular pump-out by a licensed liquid waste contractor, at a frequency set by the local water authority based on the size of the unit and the kitchen's output.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGravity grease separation\u003c\/li\u003e\n\u003cli\u003eRemoves fats, oils and grease\u003c\/li\u003e\n\u003cli\u003eRemoves suspended solids\u003c\/li\u003e\n\u003cli\u003e1500L nominal volume\u003c\/li\u003e\n\u003cli\u003eInternal pipework directed to the base of the tank\u003c\/li\u003e\n\u003cli\u003eAvoids re-suspension of settled sludge and grease\u003c\/li\u003e\n\u003cli\u003eSludge and solids settle into the base of the unit\u003c\/li\u003e\n\u003cli\u003eGrease trapped and floated to the surface\u003c\/li\u003e\n\u003cli\u003eTreated liquid discharged to sewer\u003c\/li\u003e\n\u003cli\u003ePolyethylene tank construction\u003c\/li\u003e\n\u003cli\u003e600mm square manhole\u003c\/li\u003e\n\u003cli\u003eAbove ground installation\u003c\/li\u003e\n\u003cli\u003eBelow ground installation\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003cli\u003eDual inline configuration capability\u003c\/li\u003e\n\u003cli\u003eDual parallel configuration capability\u003c\/li\u003e\n\u003cli\u003eApproved listed pre-treatment for food businesses\u003c\/li\u003e\n\u003cli\u003eApproval reference MPT\/AGA\/1500L\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConstruction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePolyethylene (poly) grease arrestor tank\u003c\/li\u003e\n\u003cli\u003e1500L volume\u003c\/li\u003e\n\u003cli\u003e2925mm length\u003c\/li\u003e\n\u003cli\u003e710mm width\u003c\/li\u003e\n\u003cli\u003e1485mm depth\u003c\/li\u003e\n\u003cli\u003e600mm square manhole\u003c\/li\u003e\n\u003cli\u003eInternal inlet pipework directed to the base of the tank\u003c\/li\u003e\n\u003cli\u003eInlet and outlet connections on opposite ends of the tank\u003c\/li\u003e\n\u003cli\u003eMoulded external ribbing for structural strength\u003c\/li\u003e\n\u003cli\u003eInlet plumbing to be installed by a licensed plumber\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003cli\u003eLid selected separately to suit the installation and load class\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLiquids Handled\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRaw sewage\u003c\/li\u003e\n\u003cli\u003eTrade waste\u003c\/li\u003e\n\u003cli\u003eEffluent\u003c\/li\u003e\n\u003cli\u003eStormwater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCafés\u003c\/li\u003e\n\u003cli\u003eRestaurants\u003c\/li\u003e\n\u003cli\u003eCanteens\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eBars and hotels\u003c\/li\u003e\n\u003cli\u003eCommercial kitchens\u003c\/li\u003e\n\u003cli\u003eFood business trade waste pre-treatment\u003c\/li\u003e\n\u003cli\u003eAbove ground grease arrestor installations\u003c\/li\u003e\n\u003cli\u003eBelow ground grease arrestor installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eContaminated water arrives through the inlet pipe.\u003c\/p\u003e\n\u003cp\u003eThe internal pipework directs that flow to the base of the tank, which avoids mixing and re-suspending sludge and grease that has already settled or risen.\u003c\/p\u003e\n\u003cp\u003eSludge and solids settle in the base of the unit.\u003c\/p\u003e\n\u003cp\u003eGrease is trapped and floats to the surface.\u003c\/p\u003e\n\u003cp\u003eTreated liquid is discharged from the grease arrestor to sewer.\u003c\/p\u003e\n\u003ch2\u003eInstallation Information\u003c\/h2\u003e\n\u003cp\u003eThe KGT1500 can be installed above ground or below ground. Inlet plumbing is to be installed by a licensed plumber, and risers are available on request where the tank sits deeper below finished surface level.\u003c\/p\u003e\n\u003cp\u003eImportant installation considerations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe water level and outlet pipe must sit 150mm below the inlet.\u003c\/li\u003e\n\u003cli\u003eThe inlet connections are on one end of the tank and the outlet connections on the opposite end.\u003c\/li\u003e\n\u003cli\u003eThe lid must be selected to match the installation type and the traffic load passing over it.\u003c\/li\u003e\n\u003cli\u003eAllow for the 2925mm length when planning the excavation or plant room location.\u003c\/li\u003e\n\u003cli\u003eSites with flows beyond a single 1500L unit may require a dual parallel or dual inline arrangement.\u003c\/li\u003e\n\u003cli\u003eSizing, trade waste approval and pump-out frequency are set by the local water authority.\u003c\/li\u003e\n\u003cli\u003eFinal sizing and installation should be approved by the relevant hydraulic consultant, engineer, licensed plumber and local authority.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eKGT1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGrease Arrestor \/ Grease Trap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e1500L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e2925mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e710mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e1485mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManhole\u003c\/td\u003e\n\u003ctd\u003e600mm Square\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (Poly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eAbove and Below Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparation Method\u003c\/td\u003e\n\u003ctd\u003eGravity Separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparated Materials\u003c\/td\u003e\n\u003ctd\u003eFats, Oils, Grease and Suspended Solids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquids Handled\u003c\/td\u003e\n\u003ctd\u003eRaw Sewage, Trade Waste, Effluent and Stormwater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Level Requirement\u003c\/td\u003e\n\u003ctd\u003e150mm Below the Inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisers\u003c\/td\u003e\n\u003ctd\u003eAvailable on Request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Plumbing\u003c\/td\u003e\n\u003ctd\u003eTo Be Installed by Plumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eListed Pre-Treatment for Food Businesses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Reference\u003c\/td\u003e\n\u003ctd\u003eMPT\/AGA\/1500L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAline Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eKwikflo Grease Trap Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eExact dimensions, nominal operating volume, lid selection and riser requirements for the KGT1500 should be confirmed against the current manufacturer's technical drawing before ordering.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Kwikflo KGT1500 1500L Polyethylene Grease Arrestor Tank\u003c\/li\u003e\n\u003cli\u003e1 x Aline Poly Lid 450mm to Suit\u003c\/li\u003e\n\u003cli\u003e1 x Aline Foam Tape\u003c\/li\u003e\n\u003cli\u003e1 x Set of Internal Inlet Pipework Directed to the Base of the Tank\u003c\/li\u003e\n\u003cli\u003e1 x 600mm Square Manhole Opening\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRisers and inlet plumbing are selected and supplied separately to suit the installation. A Class D lid configuration is available for below-ground trafficable installations. Contact our team to specify the correct lid and riser arrangement for your site.\u003c\/p\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kwikflo-kgt1500-1500l-grease-arrestor-brochure.pdf?v=1784359191\"\u003eProduct Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNeed Assistance or Ready to Order?\u003c\/h2\u003e\n\u003cp\u003eOur expert team is here to help you select the perfect setup and answer any questions. Contact us at sales@waternex.com.au or give us a call at 1300 930 847 for personalized advice and support.\u003c\/p\u003e","brand":"Kwikflow","offers":[{"title":"Default Title","offer_id":55349626634531,"sku":"KGT1500","price":4999.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kgt1500-hero.png?v=1784359174"},{"product_id":"kwikflo-kgt2000-2000l-grease-trap-arrestor-fibreglass-frp-tank","title":"Kwikflo KGT2000 2000L Grease Trap Arrestor - Fibreglass FRP Tank","description":"\u003cp\u003eThe Kwikflo KGT2000 Grease Arrestor is a 2000L fibre-reinforced polymer grease trap that removes fats, oils, grease and suspended solids from commercial kitchen wastewater before discharge to sewer. At 2000L the range steps up from polyethylene to an FRP cylindrical tank with twin 600mm access manholes, suiting high-volume kitchens, food courts and multi-tenancy premises. Rated for above ground and below ground installation and supplied by Aline Pumps under the Kwikflo Grease Separator range.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRemoves fats, oils, grease and suspended solids from trade waste\u003c\/li\u003e\n\u003cli\u003e2000L fibre-reinforced polymer (FRP) tank, model KGT2000\u003c\/li\u003e\n\u003cli\u003eTwo 600mm round access manholes for pump-out and inspection\u003c\/li\u003e\n\u003cli\u003eSuitable for both above ground and below ground installation\u003c\/li\u003e\n\u003cli\u003e100mm PVC inlet, outlet and vent connections\u003c\/li\u003e\n\u003cli\u003eCylindrical FRP construction suited to buried installation\u003c\/li\u003e\n\u003cli\u003eSeparate in-ground and above-ground support arrangements\u003c\/li\u003e\n\u003cli\u003e2600mm external length with a 1110mm internal diameter\u003c\/li\u003e\n\u003cli\u003eHandles raw sewage, trade waste, effluent and stormwater\u003c\/li\u003e\n\u003cli\u003eKwikflo Grease Separator references KGS2000AG and KGS2000BG\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Kwikflo KGT2000 2000L Grease Arrestor features and specifications\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kgt2000-feature.png?v=1784434437\"\u003e\u003c\/p\u003e\n\u003ch2\u003eWhere the Range Moves to Fibreglass\u003c\/h2\u003e\n\u003cp\u003eThe Kwikflo grease arrestors are polyethylene at 1000L and 1500L. From 2000L up they change to fibre-reinforced polymer in a cylindrical form, which handles the longer spans and the external loading of a buried tank better than a moulded poly box of the same volume.\u003c\/p\u003e\n\u003cp\u003eFor a busy kitchen, food court or multi-tenancy building, the 2000L unit gives the retention time and grease storage that smaller tanks cannot hold between scheduled pump-outs.\u003c\/p\u003e\n\u003ch2\u003eTwin Manholes for Full-Length Access\u003c\/h2\u003e\n\u003cp\u003eThe KGT2000 has two 600mm round access manholes set 700mm in from each end of the tank.\u003c\/p\u003e\n\u003cp\u003eTwo openings let a liquid waste contractor reach both the inlet and outlet halves of the tank directly, which matters on a 2580mm internal length where a single central manhole would leave the far ends hard to clear properly.\u003c\/p\u003e\n\u003ch2\u003eGravity Separation Through the Tank\u003c\/h2\u003e\n\u003cp\u003eWastewater enters through the 100mm PVC inlet and slows as it spreads across the tank's cross-section.\u003c\/p\u003e\n\u003cp\u003eSludge and heavier solids settle to the base. Grease and fats rise and are held at the surface, below the working level. The treated liquid in between leaves through the 100mm PVC outlet to sewer. A 100mm PVC vent connection maintains airflow through the tank.\u003c\/p\u003e\n\u003ch2\u003eAbove Ground or Below Ground Installation\u003c\/h2\u003e\n\u003cp\u003eThe KGT2000 is rated for both. The manufacturer's drawing shows two support arrangements: an in-ground base of 500mm and an above-ground base of 870mm, with moulded feet along the tank.\u003c\/p\u003e\n\u003cp\u003eBuried installations should be designed with the tank's cylindrical form and external loading in mind, and the access covers selected to match the traffic passing over them.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGravity grease separation\u003c\/li\u003e\n\u003cli\u003eRemoves fats, oils and grease\u003c\/li\u003e\n\u003cli\u003eRemoves suspended solids\u003c\/li\u003e\n\u003cli\u003e2000L nominal volume\u003c\/li\u003e\n\u003cli\u003eFibre-reinforced polymer tank construction\u003c\/li\u003e\n\u003cli\u003eCylindrical tank form\u003c\/li\u003e\n\u003cli\u003eTwo 600mm round access manholes\u003c\/li\u003e\n\u003cli\u003eManholes set 700mm in from each end\u003c\/li\u003e\n\u003cli\u003e200mm high manhole risers\u003c\/li\u003e\n\u003cli\u003e100mm PVC inlet connection\u003c\/li\u003e\n\u003cli\u003e100mm PVC outlet connection\u003c\/li\u003e\n\u003cli\u003e100mm PVC vent connection\u003c\/li\u003e\n\u003cli\u003eDefined internal working level\u003c\/li\u003e\n\u003cli\u003eMoulded support feet\u003c\/li\u003e\n\u003cli\u003eIn-ground support arrangement\u003c\/li\u003e\n\u003cli\u003eAbove-ground support arrangement\u003c\/li\u003e\n\u003cli\u003eAbove ground installation\u003c\/li\u003e\n\u003cli\u003eBelow ground installation\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003cli\u003eKwikflo Grease Separator KGS2000AG and KGS2000BG references\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConstruction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFibre-reinforced polymer (FRP) grease arrestor tank\u003c\/li\u003e\n\u003cli\u003e2000L volume\u003c\/li\u003e\n\u003cli\u003e2600mm external length\u003c\/li\u003e\n\u003cli\u003e2580mm internal length\u003c\/li\u003e\n\u003cli\u003e1150mm external width\u003c\/li\u003e\n\u003cli\u003e1110mm internal diameter\u003c\/li\u003e\n\u003cli\u003e1390mm overall height\u003c\/li\u003e\n\u003cli\u003e820mm internal height\u003c\/li\u003e\n\u003cli\u003eTwo 600mm round access manholes\u003c\/li\u003e\n\u003cli\u003e200mm manhole riser height\u003c\/li\u003e\n\u003cli\u003e700mm from each end to manhole centre\u003c\/li\u003e\n\u003cli\u003e100mm PVC inlet, outlet and vent sockets\u003c\/li\u003e\n\u003cli\u003e500mm in-ground support base\u003c\/li\u003e\n\u003cli\u003e870mm above-ground support base\u003c\/li\u003e\n\u003cli\u003e60mm support foot height\u003c\/li\u003e\n\u003cli\u003eInlet plumbing to be installed by a licensed plumber\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003cli\u003eLid selected separately to suit the installation and load class\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLiquids Handled\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRaw sewage\u003c\/li\u003e\n\u003cli\u003eTrade waste\u003c\/li\u003e\n\u003cli\u003eEffluent\u003c\/li\u003e\n\u003cli\u003eStormwater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCafés\u003c\/li\u003e\n\u003cli\u003eRestaurants\u003c\/li\u003e\n\u003cli\u003eCanteens\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eBars and hotels\u003c\/li\u003e\n\u003cli\u003eCommercial kitchens\u003c\/li\u003e\n\u003cli\u003eFood courts and multi-tenancy food premises\u003c\/li\u003e\n\u003cli\u003eFood business trade waste pre-treatment\u003c\/li\u003e\n\u003cli\u003eAbove ground grease arrestor installations\u003c\/li\u003e\n\u003cli\u003eBelow ground grease arrestor installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eContaminated water arrives through the 100mm PVC inlet.\u003c\/p\u003e\n\u003cp\u003eThe flow slows across the tank's cross-section, allowing separation to take place under gravity.\u003c\/p\u003e\n\u003cp\u003eSludge and solids settle in the base of the unit.\u003c\/p\u003e\n\u003cp\u003eGrease is trapped and floats to the surface, held below the working level.\u003c\/p\u003e\n\u003cp\u003eTreated liquid is discharged from the grease arrestor to sewer through the 100mm PVC outlet.\u003c\/p\u003e\n\u003ch2\u003eInstallation Information\u003c\/h2\u003e\n\u003cp\u003eThe KGT2000 can be installed above ground or below ground. Inlet plumbing is to be installed by a licensed plumber, and risers are available on request.\u003c\/p\u003e\n\u003cp\u003eImportant installation considerations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe water level and outlet pipe must sit 150mm below the inlet.\u003c\/li\u003e\n\u003cli\u003eAllow for the 2600mm external length and 1150mm width when planning the excavation or plant location.\u003c\/li\u003e\n\u003cli\u003eAbove-ground installations use the 870mm support base arrangement.\u003c\/li\u003e\n\u003cli\u003eIn-ground installations use the 500mm support base arrangement.\u003c\/li\u003e\n\u003cli\u003eBoth 600mm manholes must remain accessible for pump-out and inspection.\u003c\/li\u003e\n\u003cli\u003eAccess covers must be selected to match the traffic load passing over them.\u003c\/li\u003e\n\u003cli\u003eThe 100mm PVC vent connection must be carried through to atmosphere.\u003c\/li\u003e\n\u003cli\u003eAll drawing dimensions carry a 10mm tolerance unless otherwise stated.\u003c\/li\u003e\n\u003cli\u003eSizing, trade waste approval and pump-out frequency are set by the local water authority.\u003c\/li\u003e\n\u003cli\u003eFinal sizing and installation should be approved by the relevant hydraulic consultant, engineer, licensed plumber and local authority.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eKGT2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGrease Arrestor \/ Grease Trap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e2000L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eFibre-Reinforced Polymer (FRP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e1390mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Length\u003c\/td\u003e\n\u003ctd\u003e2600mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Length\u003c\/td\u003e\n\u003ctd\u003e2580mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Diameter\u003c\/td\u003e\n\u003ctd\u003e1110mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Height\u003c\/td\u003e\n\u003ctd\u003e820mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManhole\u003c\/td\u003e\n\u003ctd\u003e600mm Round, 2 Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManhole Riser Height\u003c\/td\u003e\n\u003ctd\u003e200mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManhole Setback\u003c\/td\u003e\n\u003ctd\u003e700mm from Each End\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Connection\u003c\/td\u003e\n\u003ctd\u003e100mm PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd\u003e100mm PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Connection\u003c\/td\u003e\n\u003ctd\u003e100mm PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Ground Support Base\u003c\/td\u003e\n\u003ctd\u003e500mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbove-Ground Support Base\u003c\/td\u003e\n\u003ctd\u003e870mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport Foot Height\u003c\/td\u003e\n\u003ctd\u003e60mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eAbove and Below Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparation Method\u003c\/td\u003e\n\u003ctd\u003eGravity Separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparated Materials\u003c\/td\u003e\n\u003ctd\u003eFats, Oils, Grease and Suspended Solids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquids Handled\u003c\/td\u003e\n\u003ctd\u003eRaw Sewage, Trade Waste, Effluent and Stormwater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensional Tolerance\u003c\/td\u003e\n\u003ctd\u003e10mm Unless Otherwise Stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrease Separator Reference\u003c\/td\u003e\n\u003ctd\u003eKGS2000AG \/ KGS2000BG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrawing Reference\u003c\/td\u003e\n\u003ctd\u003eAL19-TS20600-P \/ STS.11.26.2L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAline Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eKwikflo Grease Trap Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eExact dimensions, nominal operating volume, lid selection and riser requirements for the KGT2000 should be confirmed against the current manufacturer's technical drawing before ordering.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Kwikflo KGT2000 2000L FRP Grease Arrestor Tank\u003c\/li\u003e\n\u003cli\u003e1 x Aline Poly Lid 450mm to Suit\u003c\/li\u003e\n\u003cli\u003e1 x Aline Foam Tape\u003c\/li\u003e\n\u003cli\u003e2 x 600mm Round Access Manholes\u003c\/li\u003e\n\u003cli\u003e1 x 100mm PVC Inlet Connection\u003c\/li\u003e\n\u003cli\u003e1 x 100mm PVC Outlet Connection\u003c\/li\u003e\n\u003cli\u003e1 x 100mm PVC Vent Connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRisers and inlet plumbing are selected and supplied separately to suit the installation. A Class D lid configuration is available for below-ground trafficable installations. Contact our team to specify the correct lid and riser arrangement for your site.\u003c\/p\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kwikflo-kgt2000-2000l-grease-arrestor-brochure_0526936b-f610-4d3f-ba07-75b2bbd05903.pdf?v=1784434423\"\u003eProduct Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNeed Assistance or Ready to Order?\u003c\/h2\u003e\n\u003cp\u003eOur expert team is here to help you select the perfect setup and answer any questions. Contact us at sales@waternex.com.au or give us a call at 1300 930 847 for personalized advice and support.\u003c\/p\u003e","brand":"Kwikflow","offers":[{"title":"Default Title","offer_id":55349628404003,"sku":"KGT2000","price":5399.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kgt2000-render.png?v=1784434434"}],"url":"https:\/\/waternex.com.au\/collections\/grease-arrestors.oembed","provider":"Waternex Australia","version":"1.0","type":"link"}