{"product_id":"acequip-agm-b-80-80mm-battery-powered-electromagnetic-flow-meter","title":"Acequip AGM-B-80 80mm Battery Powered Electromagnetic Flow Meter","description":"\u003cp\u003eThe Acequip AGM-B is a battery powered electromagnetic flow meter for sites with no power at the pipe. It has no moving parts in the flow path, so there is no impeller to foul and nothing to wear out on dirty water, and it reads in both directions. Six AA batteries run it for a year in continuous use, or up to three years if the battery saving mode is left on. This is the 80 mm model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCurrently on backorder.\u003c\/strong\u003e Allow 1 to 3 weeks for dispatch. Order now to hold your place in the queue, or contact us for a current lead time.\u003c\/p\u003e\u003ch2\u003eHighlights\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo moving parts in the flow path, so no impeller to foul or wear\u003c\/li\u003e\n\u003cli\u003eRuns on six AA batteries, no mains or solar supply needed at the meter\u003c\/li\u003e\n\u003cli\u003eAccuracy of plus or minus 1 percent of reading across the top 90 percent of range\u003c\/li\u003e\n\u003cli\u003eBi-directional measurement, with total and batch volume on the display\u003c\/li\u003e\n\u003cli\u003ePolypropylene body with stainless steel electrodes, rated to 1000 kPa\u003c\/li\u003e\n\u003cli\u003eEmpty pipe detection and a battery saving sleep mode\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/AGM-B-80_card.png?v=1795407183\" alt=\"Acequip AGM-B-80 80mm Battery Powered Electromagnetic Flow Meter feature overview\"\u003e\u003c\/p\u003e\u003cp\u003eMeasurement works on Faraday's law of electromagnetic induction. The meter generates a magnetic field across the bore and reads the voltage the moving water induces between two stainless steel electrodes. Because the reading comes from the water itself rather than from a spinning rotor, the meter holds its calibration on water that would destroy a mechanical meter, and it keeps reading at low flow where an impeller would have stalled.\u003c\/p\u003e\u003cp\u003eThe 80 mm unit measures from 0.1 to 10 metres per second, which is 5.0 to 49.0 litres per second on this bore. Flow reads in cubic metres per hour, litres per second, litres per minute or gallons per minute, and volume reads as a running total and as a resettable batch. Three touch buttons on the face step through the screens, so the unit can be read and reset with gloves on.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFlow range 0.1 to 10 metres per second, full scale 5.0 to 49.0 litres per second\u003c\/li\u003e\n\u003cli\u003eAccuracy plus or minus 1 percent of reading from 100 percent down to 10 percent of full scale, and plus or minus 3 percent from 10 percent down to the cut-off\u003c\/li\u003e\n\u003cli\u003eLow flow cut-off at 2 percent of full scale\u003c\/li\u003e\n\u003cli\u003eGraphical LCD, 128 by 64 pixels, with three touch buttons\u003c\/li\u003e\n\u003cli\u003eReads flow in m3\/h, L\/s, L\/min, US gallons per minute and UK gallons per minute\u003c\/li\u003e\n\u003cli\u003eReads volume in m3, litres, US gallons and UK gallons, as total and batch\u003c\/li\u003e\n\u003cli\u003eBi-directional measurement\u003c\/li\u003e\n\u003cli\u003eEmpty pipe detection, which also protects the batteries\u003c\/li\u003e\n\u003cli\u003eBattery saving mode switches the meter off after 15 minutes of no flow\u003c\/li\u003e\n\u003cli\u003eEarthing through the third and fourth electrodes, so no separate earth ring is needed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eConstruction\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePolypropylene body with stainless steel electrodes\u003c\/li\u003e\n\u003cli\u003eElectronics protected to NEMA 4X\u003c\/li\u003e\n\u003cli\u003eSix AA alkaline batteries, user replaceable behind four cap screws\u003c\/li\u003e\n\u003cli\u003eExcitation frequency 1 per 1.67 seconds, coil resistance 100 ohm\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure 1000 kPa, which is 150 psi\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial wastewater discharge monitoring\u003c\/li\u003e\n\u003cli\u003eWater recycling systems\u003c\/li\u003e\n\u003cli\u003eIrrigation mains and sub-mains\u003c\/li\u003e\n\u003cli\u003eBore and well pump station monitoring\u003c\/li\u003e\n\u003cli\u003eAny metering point where running power to the pipe is not practical\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eA conductive liquid moving through a magnetic field induces a voltage at right angles to both. The AGM-B energises a coil around the bore and measures that induced voltage across two electrodes set in the wall of the pipe. The voltage is proportional to velocity, and velocity multiplied by the known bore area gives flow. The liquid has to conduct, so the meter needs a minimum conductivity of 20 microsiemens per centimetre. Water, wastewater and most process liquids clear that easily. Demineralised water, oils and fuels do not and cannot be measured this way.\u003c\/p\u003e\u003ch2\u003eInstallation Information\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eInstall with the FLOW arrow on the body pointing downstream\u003c\/li\u003e\n\u003cli\u003eThe bore must stay full of liquid. Mount in a rising line or in a low point, never at a high point where air can collect\u003c\/li\u003e\n\u003cli\u003eAllow straight pipe upstream and downstream of the meter so the velocity profile settles\u003c\/li\u003e\n\u003cli\u003ePorts are 80 mm BSP male. Clamp and gasket fitting kits in BSP, NPT, hose barb, quick disconnect and socket weld are available\u003c\/li\u003e\n\u003cli\u003eAmbient temperature range -12 to 54 degrees C. Media temperature range 0 to 60 degrees C\u003c\/li\u003e\n\u003cli\u003eMinimum media conductivity 20 microsiemens per centimetre\u003c\/li\u003e\n\u003cli\u003eThis meter is not NMI pattern approved. It is intended for process and site monitoring, not for trade measurement, custody transfer or licensed water extraction metering\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eAGM-B-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal size\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort connection\u003c\/td\u003e\n\u003ctd\u003e80 mm BSP male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring principle\u003c\/td\u003e\n\u003ctd\u003eElectromagnetic, Faraday induction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 10 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale\u003c\/td\u003e\n\u003ctd\u003e5.0 to 49.0 litres per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003ePlus or minus 1 percent of reading, 100 percent to 10 percent of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow flow cut-off\u003c\/td\u003e\n\u003ctd\u003e2 percent of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow direction\u003c\/td\u003e\n\u003ctd\u003eBi-directional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e6 x AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e1 year in use, up to 3 years in sleep mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eGraphical LCD 128 x 64 px, 3 touch buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum conductivity\u003c\/td\u003e\n\u003ctd\u003e20 microsiemens per cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum working pressure\u003c\/td\u003e\n\u003ctd\u003e1000 kPa (150 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003e-12 to 54 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody material\u003c\/td\u003e\n\u003ctd\u003ePolypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrodes\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronics protection\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eA 100 mm, B 180 mm, C 111 mm, bore 76.2 mm, E 185 mm, F 64.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat Is Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 x Acequip AGM-B-80 electromagnetic flow meter with integral display\u003c\/li\u003e\n\u003cli\u003e6 x AA alkaline batteries, fitted\u003c\/li\u003e\n\u003cli\u003e1 x user guide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003ePipe fittings, clamps and gaskets are ordered separately to suit your pipe connection. Contact us with your pipe type and we will quote the matching kit.\u003c\/p\u003e\u003ch2\u003eWarranty\u003c\/h2\u003e\u003cp\u003e12 month manufacturer warranty against defects in materials and workmanship. Batteries are a consumable and are not covered.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/acequip-agm-user-guide.pdf?v=1795407178\"\u003eAcequip AGM User Guide\u003c\/a\u003e\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eNeed Assistance or Ready to Order?\u003c\/h2\u003e\u003cp\u003eOur team sizes this equipment every week and is happy to check it against your duty before you buy. Email \u003ca href=\"mailto:sales@waternex.com.au\"\u003esales@waternex.com.au\u003c\/a\u003e or call \u003ca href=\"tel:1300930847\"\u003e1300 930 847\u003c\/a\u003e.\u003c\/p\u003e","brand":"Acequip","offers":[{"title":"Default Title","offer_id":56125580706083,"sku":"AGM-B-80","price":2881.8,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/AGM-B-80.png?v=1795407191","url":"https:\/\/waternex.com.au\/products\/acequip-agm-b-80-80mm-battery-powered-electromagnetic-flow-meter","provider":"Waternex Australia","version":"1.0","type":"link"}