{"product_id":"gws-pressurewave-pwb-35lv-35l-10-bar-vertical-pressure-tank","title":"GWS PressureWave PWB-35LV 35L 10 Bar Vertical Pressure Tank","description":"\u003cp\u003eThe GWS PressureWave PWB-35LV is a 35 litre vertical diaphragm pressure tank rated to 10 bar, standing on its own moulded base. The diaphragm keeps the water off the steel, so there is nothing inside to corrode and nothing to service beyond checking the precharge once a year.\u003c\/p\u003e\u003ch2\u003eHighlights\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e35 litre nominal volume, drawdown approximately 10 litres\u003c\/li\u003e\n\u003cli\u003eFree standing on a moulded base with a lifting aperture\u003c\/li\u003e\n\u003cli\u003eRated to 10 bar, which is 150 psi\u003c\/li\u003e\n\u003cli\u003eAS 4020 approved and WaterMark approved for drinking water\u003c\/li\u003e\n\u003cli\u003eHigh grade butyl diaphragm over a virgin polypropylene liner\u003c\/li\u003e\n\u003cli\u003ePatented stainless steel water connection\u003c\/li\u003e\n\u003cli\u003eFactory precharged to 1.9 bar, maintenance free in service\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/PWB-35LV_card.png?v=1795493556\" alt=\"GWS PressureWave PWB-35LV 35L 10 Bar Vertical Pressure Tank feature overview\"\u003e\u003c\/p\u003e\u003cp\u003eA pressure tank does two jobs. It stores water under pressure so the pump does not restart for every small draw, and it cushions the pressure spikes that travel back through the pipework as water hammer. Both jobs cut the number of starts the pump makes, and starts are what wear a pump out. On a correctly sized and correctly precharged tank the pump runs longer and less often, which is easier on the motor, the seals and the switchgear.\u003c\/p\u003e\u003cp\u003eThe PressureWave series is the general purpose line. Where the Max and UltraMax tanks are built in thicker steel for 16 and 25 bar duty, PressureWave covers the 10 bar applications that make up most domestic and light commercial work, at a price that reflects it. The V suffix means the tank stands vertically on a base rather than hanging on the pipe.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMaximum working pressure 10 bar (150 psi)\u003c\/li\u003e\n\u003cli\u003eFactory precharge 1.9 bar (28 psi)\u003c\/li\u003e\n\u003cli\u003eMaximum working temperature 90 degrees C, minimum -10 degrees C\u003c\/li\u003e\n\u003cli\u003eHigh grade butyl diaphragm\u003c\/li\u003e\n\u003cli\u003eVirgin polypropylene liner\u003c\/li\u003e\n\u003cli\u003ePatented stainless steel water connection\u003c\/li\u003e\n\u003cli\u003eLeak free O-ring sealed air valve cap\u003c\/li\u003e\n\u003cli\u003eDual layer polyurethane paint finish over an epoxy undercoat\u003c\/li\u003e\n\u003cli\u003eMaintenance free in service\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eConstruction\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCarbon steel shell with a dual layer polyurethane finish in almond\u003c\/li\u003e\n\u003cli\u003eVirgin polypropylene liner\u003c\/li\u003e\n\u003cli\u003eHigh grade butyl diaphragm\u003c\/li\u003e\n\u003cli\u003ePatented stainless steel water connection\u003c\/li\u003e\n\u003cli\u003eReinforced thermoplastic base with a lifting aperture\u003c\/li\u003e\n\u003cli\u003eLeak free O-ring sealed air valve cap\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDomestic pressure pump systems\u003c\/li\u003e\n\u003cli\u003eRainwater and bore water supply\u003c\/li\u003e\n\u003cli\u003eSmall to medium irrigation systems\u003c\/li\u003e\n\u003cli\u003eLight commercial pressure boosting\u003c\/li\u003e\n\u003cli\u003eProtection against water hammer\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eThe tank is divided by a butyl diaphragm. One side holds air at the precharge pressure, the other fills with water. As the pump runs, water enters and compresses the air. When a tap opens, the compressed air pushes that water back out before the pump needs to start. The precharge decides how much water the tank actually gives back, which is why it is set just under the pump cut-in pressure. A tank at the wrong precharge will short cycle the pump no matter how large it is.\u003c\/p\u003e\u003ch2\u003eInstallation Information\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMount vertically on the supplied base, on a level and solid surface\u003c\/li\u003e\n\u003cli\u003eCheck the precharge with the water side drained. Factory setting is 1.9 bar\u003c\/li\u003e\n\u003cli\u003eSet the precharge to roughly 0.2 bar below the pump cut-in pressure, then recheck annually\u003c\/li\u003e\n\u003cli\u003eFit an isolating valve and a drain between the tank and the system so the precharge can be checked without draining the main\u003c\/li\u003e\n\u003cli\u003eDo not exceed 10 bar working pressure, and do not allow the tank to freeze\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003ePWB-35LV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eGWS PressureWave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal volume\u003c\/td\u003e\n\u003ctd\u003e35 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrawdown\u003c\/td\u003e\n\u003ctd\u003eapproximately 10 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum working pressure\u003c\/td\u003e\n\u003ctd\u003e10 bar (150 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory precharge\u003c\/td\u003e\n\u003ctd\u003e1.9 bar (28 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum working temperature\u003c\/td\u003e\n\u003ctd\u003e90 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum working temperature\u003c\/td\u003e\n\u003ctd\u003e-10 degrees C, avoid freezing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003e1 inch BSPP female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrientation\u003c\/td\u003e\n\u003ctd\u003eVertical, free standing with base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiaphragm\u003c\/td\u003e\n\u003ctd\u003eHigh grade butyl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiner\u003c\/td\u003e\n\u003ctd\u003eVirgin polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e555 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003e318 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eAS 4020 drinking water, WaterMark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat Is Included\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1 x GWS PressureWave PWB-35LV pressure tank with base fitted\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eWarranty\u003c\/h2\u003e\u003cp\u003e5 year manufacturer warranty against defects in materials and workmanship, subject to the tank being operated within its rated pressure and temperature and to the precharge being maintained.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/gws-pressurewave-datasheet_13baa295-1694-49f9-8559-47e8d0ffa195.pdf?v=1795493529\"\u003eGWS PressureWave Series Datasheet\u003c\/a\u003e\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eNeed Assistance or Ready to Order?\u003c\/h2\u003e\u003cp\u003eOur team sizes this equipment every week and is happy to check it against your duty before you buy. Email \u003ca href=\"mailto:sales@waternex.com.au\"\u003esales@waternex.com.au\u003c\/a\u003e or call \u003ca href=\"tel:1300930847\"\u003e1300 930 847\u003c\/a\u003e.\u003c\/p\u003e","brand":"Global Water Solutions","offers":[{"title":"Default Title","offer_id":56135804846371,"sku":"PWB-35LV","price":239.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/PWB-35LV.png?v=1795493560","url":"https:\/\/waternex.com.au\/products\/gws-pressurewave-pwb-35lv-35l-10-bar-vertical-pressure-tank","provider":"Waternex Australia","version":"1.0","type":"link"}