{"product_id":"kcps-1500-oil-water-separator-1500l-poly-tank-system","title":"KCPS-1500 Oil Water Separator 1500L Poly Tank System","description":"\u003cp\u003ehe Aline KCPS-1500 Oil Water Separator provides reliable pre-treatment for wastewater containing free oil and suspended solids. Its coalescing plate system separates oil, water and settled material before the wastewater is discharged to sewer, making it well suited to workshops, wash bays, service facilities and industrial sites.\u003c\/p\u003e\n\u003ch3\u003eHighlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSeparates free oil and suspended solids from wastewater\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoalescing plate technology captures smaller oil droplets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy solids settle into a dedicated sludge hopper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical-resistant, UV-stabilised polyethylene construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGalvanised support frame for freestanding installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate outlets for treated water, collected oil and sludge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for indoor, outdoor and pumping-to-sewer installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManual or automatic oil removal options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStraightforward servicing with removable plate packs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous-area configurations available for suitable installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"float: none;\" alt=\"KCPS-1500 Oil Water Separator 1500L Poly Tank System feature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/KCPS_1500_oil_and_water_separator.png?v=1784177793\"\u003e\u003c\/div\u003e\n\u003ch3\u003eBetter Separation Before Wastewater Reaches the Sewer\u003c\/h3\u003e\n\u003cp\u003eOily wastewater cannot normally be discharged without suitable pre-treatment. The KCPS-1500 separates free oil and suspended solids from the wastewater stream before it reaches the sewer connection.\u003c\/p\u003e\n\u003cp\u003eThis helps workshops and commercial facilities manage oily wastewater more effectively while providing a dedicated system for collecting separated oil and settled sludge.\u003c\/p\u003e\n\u003ch3\u003eCoalescing Plates Capture Smaller Oil Droplets\u003c\/h3\u003e\n\u003cp\u003eWastewater enters the separator through the inlet chamber, where heavier solids settle and larger oil slugs rise to the surface.\u003c\/p\u003e\n\u003cp\u003eThe remaining wastewater then passes through a stack of closely spaced, corrugated polypropylene plates. These oleophilic plates attract and combine smaller oil droplets, helping them rise to the surface for collection. Fine solids are also progressively separated as the wastewater moves through the plate pack.\u003c\/p\u003e\n\u003cp\u003eA downstream baffle or oil dam prevents the collected oil from passing into the treated-water outlet.\u003c\/p\u003e\n\u003ch3\u003eSeparate Access for Oil, Water and Sludge\u003c\/h3\u003e\n\u003cp\u003eThe KCPS-1500 includes dedicated connections for each part of the separation process.\u003c\/p\u003e\n\u003cp\u003eTreated wastewater leaves through the 50mm sewer outlet, separated oil is directed through its own 50mm outlet, and settled material can be removed through the sludge hopper and integrated 50mm PVC ball valve.\u003c\/p\u003e\n\u003cp\u003eOil skimmers may be used for either manual or automatic oil removal, depending on the installation design.\u003c\/p\u003e\n\u003ch3\u003eBuilt for Demanding Commercial Environments\u003c\/h3\u003e\n\u003cp\u003eThe separator is available with a polyethylene or stainless steel tank. The polyethylene version uses chemical-resistant, UV-stabilised material with a 5mm tank wall and 5mm lid.\u003c\/p\u003e\n\u003cp\u003eA galvanised mild-steel support frame provides a stable freestanding structure, while UPVC inlet, outlet and drain connections offer good resistance to corrosion and wastewater exposure.\u003c\/p\u003e\n\u003ch3\u003eStraightforward Access and Maintenance\u003c\/h3\u003e\n\u003cp\u003eUnder normal operating conditions, the main maintenance requirement is regular cleaning of the polypropylene plate packs with hot water.\u003c\/p\u003e\n\u003cp\u003eThe removable lid and quick-release fasteners provide access to the internal components, while the sludge drain and oil outlet allow collected material to be removed without dismantling the complete separator.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnhanced gravity oil and water separation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoalescing plate separator design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemoves free oils and suspended solids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparates larger oil slugs at the inlet chamber\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCaptures smaller oil droplets through the plate pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAllows heavier solids to settle into the sludge hopper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClosely spaced corrugated polypropylene plates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOleophilic plate-pack material\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDownstream baffle or oil dam\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDedicated treated-water outlet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDedicated collected-oil outlet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDedicated sludge drain\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManual or automatic oil-skimmer compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemovable lid for servicing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuick-release fasteners\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGalvanised support frame\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBolt-down mounting feet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical-resistant construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUV-stabilised polyethylene tank and lid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePolyethylene or stainless steel tank options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow routine maintenance requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for indoor and outdoor installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for pumping-to-sewer arrangements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExplosion-proof installation options available when correctly configured\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConstruction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePolyethylene or stainless steel separator tank\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical-resistant UV-stabilised polyethylene tank\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5mm polyethylene tank thickness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical-resistant UV-stabilised polyethylene lid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5mm polyethylene lid thickness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemovable polyethylene lid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGalvanised mild-steel support frame\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMild-steel SHS frame construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOleophilic corrugated polypropylene plate pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e32mm pressure UPVC CAT 17 inlet socket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50mm DWV UPVC V66 treated-water outlet socket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50mm DWV UPVC V66 oil outlet socket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50mm UPVC sludge hopper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated 50mm PVC ball valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuick-release DZUS fasteners\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBolt-down mounting feet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical workshops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomotive workshops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVehicle service centres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial wash bays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEquipment washdown areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery maintenance facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing sites\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommercial wastewater pre-treatment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial wastewater pre-treatment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFacilities producing oily wastewater\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePumping-to-sewer systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndoor oil-water separation installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutdoor oil-water separation installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous-area installations when appropriately configured\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eOily wastewater is introduced into the separator’s inlet chamber by a pump.\u003c\/p\u003e\n\u003cp\u003eHeavy solids settle into the sludge hopper, while larger or concentrated oil slugs rise directly to the surface. The remaining oil-and-water mixture flows through the corrugated polypropylene plate pack.\u003c\/p\u003e\n\u003cp\u003eAs the wastewater passes between the plates, smaller oil droplets combine and rise to the surface. Fine solids progressively settle away from the treated water.\u003c\/p\u003e\n\u003cp\u003eA baffle or oil dam prevents separated oil from entering the outlet weir. Treated wastewater then leaves through the sewer outlet, while oil and sludge are removed through their dedicated connections.\u003c\/p\u003e\n\u003ch2\u003eInstallation Information\u003c\/h2\u003e\n\u003cp\u003eThe KCPS-1500 may be incorporated into indoor, outdoor, pumping-to-sewer or hazardous-area wastewater systems.\u003c\/p\u003e\n\u003cp\u003eTypical installations may include a diaphragm pump, float level switch, oil collection container, electrical conduit, suction pipe, discharge pipe and a separate collection or pump pit.\u003c\/p\u003e\n\u003cp\u003eEach system should be selected and installed according to the site wastewater flow, oil loading, solids loading, discharge requirements and local authority conditions.\u003c\/p\u003e\n\u003cp\u003eImportant installation requirements include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe installation should be bunded with enough capacity to contain the separator volume.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe bunded area should prevent rainwater from entering the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe separator and associated pit may be classified as a Class 1, Zone 2 hazardous area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe hazardous area may extend 500mm above the separator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAny float switch used in the system must be oil proof.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTypical arrangements show a discharge pit with a minimum 500-litre working volume.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTypical indoor arrangements show a minimum 2000mm separation distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTypical outdoor arrangements show a minimum 500mm separation distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous-area installations require suitable explosion-protected electrical equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal design and installation should be confirmed by the relevant hydraulic consultant, engineer, plumber and approving authority.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKCPS-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCoalescing Plate Oil Water Separator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Size\u003c\/td\u003e\n\u003ctd\u003e1500L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparation Method\u003c\/td\u003e\n\u003ctd\u003eEnhanced Gravity Separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparated Materials\u003c\/td\u003e\n\u003ctd\u003eFree Oil and Suspended Solids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene or Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolyethylene Tank Construction\u003c\/td\u003e\n\u003ctd\u003eChemical-Resistant UV-Stabilised Polyethylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank Thickness\u003c\/td\u003e\n\u003ctd\u003e5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid Material\u003c\/td\u003e\n\u003ctd\u003eChemical-Resistant UV-Stabilised Polyethylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid Thickness\u003c\/td\u003e\n\u003ctd\u003e5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Connection\u003c\/td\u003e\n\u003ctd\u003e32mm Pressure UPVC CAT 17 Socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreated-Water Outlet\u003c\/td\u003e\n\u003ctd\u003e50mm DWV UPVC V66 Socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil Outlet\u003c\/td\u003e\n\u003ctd\u003e50mm DWV UPVC V66 Socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSludge Hopper\u003c\/td\u003e\n\u003ctd\u003e50mm UPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSludge Drain Valve\u003c\/td\u003e\n\u003ctd\u003e50mm PVC Ball Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate-Pack Material\u003c\/td\u003e\n\u003ctd\u003eOleophilic Corrugated Polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003eGalvanised Mild Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess\u003c\/td\u003e\n\u003ctd\u003eRemovable Lid with Quick-Release Fasteners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFreestanding Frame with Bolt-Down Feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoutine Plate-Pack Cleaning\u003c\/td\u003e\n\u003ctd\u003eHot-Water Cleaning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Types\u003c\/td\u003e\n\u003ctd\u003eIndoor, Outdoor, Pumping to Sewer and Hazardous-Area Configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Hazardous-Area Classification\u003c\/td\u003e\n\u003ctd\u003eClass 1, Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Hazardous-Area Extent\u003c\/td\u003e\n\u003ctd\u003e500mm Above the Separator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloat-Switch Requirement\u003c\/td\u003e\n\u003ctd\u003eOil Proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Minimum Pit Working Volume\u003c\/td\u003e\n\u003ctd\u003e500 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eExact dimensions, nominal operating volume, separator flow capacity and weight for the KCPS-1500 should be confirmed against the current manufacturer’s technical drawing before ordering.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Aline KCPS-1500 Oil Water Separator Tank\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Galvanised Support Frame\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Oleophilic Polypropylene Coalescing Plate Pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Diaphragm Pump\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Float Level Switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Removable Polyethylene Lid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Sludge Hopper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 50mm PVC Sludge Drain Ball Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Set of In-Tank Fittings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 32mm UPVC Inlet Connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 50mm UPVC Treated-Water Outlet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 50mm UPVC Oil Outlet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/1000L-Brochure-2_1.pdf?v=1784173803\"\u003eAline Oil Water Separator Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"3036\" data-start=\"3002\"\u003eNeed Assistance or Ready to Order?\u003c\/h3\u003e\n\u003cp data-end=\"3251\" data-start=\"3038\"\u003eOur expert team is here to help you select the perfect setup and answer any questions. Contact us at \u003ca rel=\"noopener\" class=\"decorated-link cursor-pointer\" data-end=\"3165\" data-start=\"3144\"\u003esales@waternex.com.au\u003c\/a\u003e or give us a call at 1300 930 847 for personalized advice and support.\u003c\/p\u003e","brand":"Waternex Australia","offers":[{"title":"Default Title","offer_id":55342341062947,"sku":null,"price":6720.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/KCPS-1500_Oil_Water_Separator_1500L_Poly_Tank_System.png?v=1784177866","url":"https:\/\/waternex.com.au\/products\/kcps-1500-oil-water-separator-1500l-poly-tank-system","provider":"Waternex Australia","version":"1.0","type":"link"}