{"product_id":"kwikflo-kgt1000-1000l-grease-trap-arrestor-above-below-ground","title":"Kwikflo KGT1000 1000L Grease Trap Arrestor - Above \u0026 Below Ground","description":"\u003cp\u003eThe Kwikflo KGT1000 Grease Arrestor is a 1000L polyethylene grease trap built to remove fats, oils, grease and suspended solids from commercial kitchen wastewater before it reaches the sewer. It suits above ground and below ground installation, making it a practical fit for cafés, restaurants, canteens, hospitals, bars and hotels that need a certified pre-treatment stage. Manufactured by Aline Pumps, the Kwikflo range is an approved listed pre-treatment product for food businesses.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRemoves fats, oils, grease and suspended solids from trade waste\u003c\/li\u003e\n\u003cli\u003e1000L polyethylene tank, model KGT1000\u003c\/li\u003e\n\u003cli\u003eSuitable for both above ground and below ground installation\u003c\/li\u003e\n\u003cli\u003eApproved listed pre-treatment for food businesses\u003c\/li\u003e\n\u003cli\u003eInternal pipework directs flow to the base of the tank to avoid re-suspending settled sludge\u003c\/li\u003e\n\u003cli\u003e600mm square manhole for access and servicing\u003c\/li\u003e\n\u003cli\u003eWide range of lid options from Class B through to Class D load ratings\u003c\/li\u003e\n\u003cli\u003eRisers available on request for deeper below-ground installs\u003c\/li\u003e\n\u003cli\u003eHandles raw sewage, trade waste, effluent and stormwater\u003c\/li\u003e\n\u003cli\u003eCompact 2060mm x 710mm footprint\u003c\/li\u003e\n\u003cli\u003ePart of the Kwikflo range spanning 1000L to 5000L, with custom fibreglass sizes available\u003c\/li\u003e\n\u003cli\u003eCan be configured in dual inline or dual parallel arrangements for higher flows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kgt1000-feature.png?v=1784357563\" alt=\"Kwikflo KGT1000 1000L Grease Arrestor features and specifications\"\u003e\u003c\/p\u003e\n\u003ch2\u003eProven Grease Separation for Commercial Kitchens\u003c\/h2\u003e\n\u003cp\u003eCommercial kitchens push a constant load of fats, oils and grease into their drainage. Left untreated, that material cools and hardens in the sewer line, which is why water authorities require food businesses to install a grease arrestor as a pre-treatment stage.\u003c\/p\u003e\n\u003cp\u003eThe KGT1000 gives cafés, restaurants and institutional kitchens a 1000L holding volume where that separation happens under gravity, before the wastewater is discharged to sewer.\u003c\/p\u003e\n\u003ch2\u003eInternal Pipework That Protects the Settled Layers\u003c\/h2\u003e\n\u003cp\u003eContaminated water arrives through the inlet pipe and is directed by the internal pipework down to the base of the tank.\u003c\/p\u003e\n\u003cp\u003eFeeding the flow low into the tank avoids stirring up sludge and grease that has already separated. Without this, incoming water would mix the tank contents and carry separated material back toward the outlet.\u003c\/p\u003e\n\u003cp\u003eInside the tank, the wastewater slows and separates into three layers. Sludge and heavier solids settle into the base of the unit, grease is trapped and floats to the surface, and the treated liquid in the middle is discharged from the grease arrestor to sewer.\u003c\/p\u003e\n\u003ch2\u003eAbove Ground or Below Ground Installation\u003c\/h2\u003e\n\u003cp\u003eThe KGT1000 is rated for both above ground and below ground installation, so it can sit in a plant room, service yard, or be buried under a trafficable area with the appropriate lid.\u003c\/p\u003e\n\u003cp\u003eFor sites with higher flows than a single 1000L unit can handle, the Kwikflo range supports dual parallel and dual inline configurations, and steps up through 1500L poly to 2000L, 3000L, 4000L and 5000L fibre-reinforced polymer models.\u003c\/p\u003e\n\u003ch2\u003eStraightforward Servicing Access\u003c\/h2\u003e\n\u003cp\u003eA 600mm square manhole gives access for pump-out and inspection. Grease arrestors need regular pump-out by a licensed liquid waste contractor, at a frequency set by the local water authority based on the size of the unit and the kitchen's output.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGravity grease separation\u003c\/li\u003e\n\u003cli\u003eRemoves fats, oils and grease\u003c\/li\u003e\n\u003cli\u003eRemoves suspended solids\u003c\/li\u003e\n\u003cli\u003e1000L nominal volume\u003c\/li\u003e\n\u003cli\u003eInternal pipework directed to the base of the tank\u003c\/li\u003e\n\u003cli\u003eAvoids re-suspension of settled sludge and grease\u003c\/li\u003e\n\u003cli\u003eSludge and solids settle into the base of the unit\u003c\/li\u003e\n\u003cli\u003eGrease trapped and floated to the surface\u003c\/li\u003e\n\u003cli\u003eTreated liquid discharged to sewer\u003c\/li\u003e\n\u003cli\u003ePolyethylene tank construction\u003c\/li\u003e\n\u003cli\u003e600mm square manhole\u003c\/li\u003e\n\u003cli\u003eAbove ground installation\u003c\/li\u003e\n\u003cli\u003eBelow ground installation\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003cli\u003eMultiple lid options across Class B and Class D ratings\u003c\/li\u003e\n\u003cli\u003eDual inline configuration capability\u003c\/li\u003e\n\u003cli\u003eDual parallel configuration capability\u003c\/li\u003e\n\u003cli\u003eApproved listed pre-treatment for food businesses\u003c\/li\u003e\n\u003cli\u003ePart of a range extending from 1000L to 5000L\u003c\/li\u003e\n\u003cli\u003eCustom fibreglass sizes available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConstruction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePolyethylene (poly) grease arrestor tank\u003c\/li\u003e\n\u003cli\u003e1000L volume\u003c\/li\u003e\n\u003cli\u003e2060mm length\u003c\/li\u003e\n\u003cli\u003e710mm width\u003c\/li\u003e\n\u003cli\u003e1485mm depth\u003c\/li\u003e\n\u003cli\u003e600mm square manhole\u003c\/li\u003e\n\u003cli\u003eInternal inlet pipework directed to the base of the tank\u003c\/li\u003e\n\u003cli\u003eInlet and outlet connections on opposite ends of the tank\u003c\/li\u003e\n\u003cli\u003eMoulded external ribbing for structural strength\u003c\/li\u003e\n\u003cli\u003eInlet plumbing to be installed by a licensed plumber\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003cli\u003eLid selected separately to suit the installation and load class\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLiquids Handled\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRaw sewage\u003c\/li\u003e\n\u003cli\u003eTrade waste\u003c\/li\u003e\n\u003cli\u003eEffluent\u003c\/li\u003e\n\u003cli\u003eStormwater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCafés\u003c\/li\u003e\n\u003cli\u003eRestaurants\u003c\/li\u003e\n\u003cli\u003eCanteens\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eBars and hotels\u003c\/li\u003e\n\u003cli\u003eCommercial kitchens\u003c\/li\u003e\n\u003cli\u003eFood business trade waste pre-treatment\u003c\/li\u003e\n\u003cli\u003eAbove ground grease arrestor installations\u003c\/li\u003e\n\u003cli\u003eBelow ground grease arrestor installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eContaminated water arrives through the inlet pipe.\u003c\/p\u003e\n\u003cp\u003eThe internal pipework directs that flow to the base of the tank, which avoids mixing and re-suspending sludge and grease that has already settled or risen.\u003c\/p\u003e\n\u003cp\u003eSludge and solids settle in the base of the unit.\u003c\/p\u003e\n\u003cp\u003eGrease is trapped and floats to the surface.\u003c\/p\u003e\n\u003cp\u003eTreated liquid is discharged from the grease arrestor to sewer.\u003c\/p\u003e\n\u003ch2\u003eInstallation Information\u003c\/h2\u003e\n\u003cp\u003eThe KGT1000 can be installed above ground or below ground. Inlet plumbing is to be installed by a licensed plumber, and risers are available on request where the tank sits deeper below finished surface level.\u003c\/p\u003e\n\u003cp\u003eImportant installation considerations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe water level and outlet pipe must sit 150mm below the inlet.\u003c\/li\u003e\n\u003cli\u003eThe inlet connections are on one end of the tank and the outlet connections on the opposite end.\u003c\/li\u003e\n\u003cli\u003eThe lid must be selected to match the installation type and the traffic load passing over it.\u003c\/li\u003e\n\u003cli\u003eBelow ground installations require a load-rated cover, with Class B and Class D options available.\u003c\/li\u003e\n\u003cli\u003eAbove ground installations can use the poly or fibreglass 600x600 lid, or the 200mm poly inspection port lid.\u003c\/li\u003e\n\u003cli\u003eSites with flows beyond a single 1000L unit may require a dual parallel or dual inline arrangement.\u003c\/li\u003e\n\u003cli\u003eSizing, trade waste approval and pump-out frequency are set by the local water authority.\u003c\/li\u003e\n\u003cli\u003eFinal sizing and installation should be approved by the relevant hydraulic consultant, engineer, licensed plumber and local authority.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eKGT1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGrease Arrestor \/ Grease Trap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e1000L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e2060mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e710mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e1485mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManhole\u003c\/td\u003e\n\u003ctd\u003e600mm Square\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (Poly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eAbove and Below Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparation Method\u003c\/td\u003e\n\u003ctd\u003eGravity Separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparated Materials\u003c\/td\u003e\n\u003ctd\u003eFats, Oils, Grease and Suspended Solids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquids Handled\u003c\/td\u003e\n\u003ctd\u003eRaw Sewage, Trade Waste, Effluent and Stormwater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Level Requirement\u003c\/td\u003e\n\u003ctd\u003e150mm Below the Inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisers\u003c\/td\u003e\n\u003ctd\u003eAvailable on Request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Plumbing\u003c\/td\u003e\n\u003ctd\u003eTo Be Installed by Plumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eListed Pre-Treatment for Food Businesses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Reference\u003c\/td\u003e\n\u003ctd\u003eMPT\/AGA\/1000L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAline Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eKwikflo Grease Trap Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eExact dimensions, nominal operating volume, lid selection and riser requirements for the KGT1000 should be confirmed against the current manufacturer's technical drawing before ordering.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Kwikflo KGT1000 1000L Polyethylene Grease Arrestor Tank\u003c\/li\u003e\n\u003cli\u003e1 x Set of Internal Inlet Pipework Directed to the Base of the Tank\u003c\/li\u003e\n\u003cli\u003e1 x 600mm Square Manhole Opening\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLids, risers and inlet plumbing are selected and supplied separately to suit the installation. Contact our team to specify the correct lid class and riser configuration for your site.\u003c\/p\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kwikflo-kgt1000-1000l-grease-arrestor-brochure.pdf?v=1784358230\"\u003eProduct Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eNeed Assistance or Ready to Order?\u003c\/h2\u003e\n\u003cp\u003eOur expert team is here to help you select the perfect setup and answer any questions. Contact us at sales@waternex.com.au or give us a call at 1300 930 847 for personalized advice and support.\u003c\/p\u003e","brand":"Kwikflow","offers":[{"title":"Default Title","offer_id":55349190918435,"sku":"KGT1000","price":2999.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kgt1000-hero.png?v=1784357560","url":"https:\/\/waternex.com.au\/products\/kwikflo-kgt1000-1000l-grease-trap-arrestor-above-below-ground","provider":"Waternex Australia","version":"1.0","type":"link"}