{"product_id":"kwikflo-kgt2000-2000l-grease-trap-arrestor-fibreglass-frp-tank","title":"Kwikflo KGT2000 2000L Grease Trap Arrestor - Fibreglass FRP Tank","description":"\u003cp\u003eThe Kwikflo KGT2000 Grease Arrestor is a 2000L fibre-reinforced polymer grease trap that removes fats, oils, grease and suspended solids from commercial kitchen wastewater before discharge to sewer. At 2000L the range steps up from polyethylene to an FRP cylindrical tank with twin 600mm access manholes, suiting high-volume kitchens, food courts and multi-tenancy premises. Rated for above ground and below ground installation and supplied by Aline Pumps under the Kwikflo Grease Separator range.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRemoves fats, oils, grease and suspended solids from trade waste\u003c\/li\u003e\n\u003cli\u003e2000L fibre-reinforced polymer (FRP) tank, model KGT2000\u003c\/li\u003e\n\u003cli\u003eTwo 600mm round access manholes for pump-out and inspection\u003c\/li\u003e\n\u003cli\u003eSuitable for both above ground and below ground installation\u003c\/li\u003e\n\u003cli\u003e100mm PVC inlet, outlet and vent connections\u003c\/li\u003e\n\u003cli\u003eCylindrical FRP construction suited to buried installation\u003c\/li\u003e\n\u003cli\u003eSeparate in-ground and above-ground support arrangements\u003c\/li\u003e\n\u003cli\u003e2600mm external length with a 1110mm internal diameter\u003c\/li\u003e\n\u003cli\u003eHandles raw sewage, trade waste, effluent and stormwater\u003c\/li\u003e\n\u003cli\u003eKwikflo Grease Separator references KGS2000AG and KGS2000BG\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Kwikflo KGT2000 2000L Grease Arrestor features and specifications\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kgt2000-feature.png?v=1784434437\"\u003e\u003c\/p\u003e\n\u003ch2\u003eWhere the Range Moves to Fibreglass\u003c\/h2\u003e\n\u003cp\u003eThe Kwikflo grease arrestors are polyethylene at 1000L and 1500L. From 2000L up they change to fibre-reinforced polymer in a cylindrical form, which handles the longer spans and the external loading of a buried tank better than a moulded poly box of the same volume.\u003c\/p\u003e\n\u003cp\u003eFor a busy kitchen, food court or multi-tenancy building, the 2000L unit gives the retention time and grease storage that smaller tanks cannot hold between scheduled pump-outs.\u003c\/p\u003e\n\u003ch2\u003eTwin Manholes for Full-Length Access\u003c\/h2\u003e\n\u003cp\u003eThe KGT2000 has two 600mm round access manholes set 700mm in from each end of the tank.\u003c\/p\u003e\n\u003cp\u003eTwo openings let a liquid waste contractor reach both the inlet and outlet halves of the tank directly, which matters on a 2580mm internal length where a single central manhole would leave the far ends hard to clear properly.\u003c\/p\u003e\n\u003ch2\u003eGravity Separation Through the Tank\u003c\/h2\u003e\n\u003cp\u003eWastewater enters through the 100mm PVC inlet and slows as it spreads across the tank's cross-section.\u003c\/p\u003e\n\u003cp\u003eSludge and heavier solids settle to the base. Grease and fats rise and are held at the surface, below the working level. The treated liquid in between leaves through the 100mm PVC outlet to sewer. A 100mm PVC vent connection maintains airflow through the tank.\u003c\/p\u003e\n\u003ch2\u003eAbove Ground or Below Ground Installation\u003c\/h2\u003e\n\u003cp\u003eThe KGT2000 is rated for both. The manufacturer's drawing shows two support arrangements: an in-ground base of 500mm and an above-ground base of 870mm, with moulded feet along the tank.\u003c\/p\u003e\n\u003cp\u003eBuried installations should be designed with the tank's cylindrical form and external loading in mind, and the access covers selected to match the traffic passing over them.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGravity grease separation\u003c\/li\u003e\n\u003cli\u003eRemoves fats, oils and grease\u003c\/li\u003e\n\u003cli\u003eRemoves suspended solids\u003c\/li\u003e\n\u003cli\u003e2000L nominal volume\u003c\/li\u003e\n\u003cli\u003eFibre-reinforced polymer tank construction\u003c\/li\u003e\n\u003cli\u003eCylindrical tank form\u003c\/li\u003e\n\u003cli\u003eTwo 600mm round access manholes\u003c\/li\u003e\n\u003cli\u003eManholes set 700mm in from each end\u003c\/li\u003e\n\u003cli\u003e200mm high manhole risers\u003c\/li\u003e\n\u003cli\u003e100mm PVC inlet connection\u003c\/li\u003e\n\u003cli\u003e100mm PVC outlet connection\u003c\/li\u003e\n\u003cli\u003e100mm PVC vent connection\u003c\/li\u003e\n\u003cli\u003eDefined internal working level\u003c\/li\u003e\n\u003cli\u003eMoulded support feet\u003c\/li\u003e\n\u003cli\u003eIn-ground support arrangement\u003c\/li\u003e\n\u003cli\u003eAbove-ground support arrangement\u003c\/li\u003e\n\u003cli\u003eAbove ground installation\u003c\/li\u003e\n\u003cli\u003eBelow ground installation\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003cli\u003eKwikflo Grease Separator KGS2000AG and KGS2000BG references\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConstruction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFibre-reinforced polymer (FRP) grease arrestor tank\u003c\/li\u003e\n\u003cli\u003e2000L volume\u003c\/li\u003e\n\u003cli\u003e2600mm external length\u003c\/li\u003e\n\u003cli\u003e2580mm internal length\u003c\/li\u003e\n\u003cli\u003e1150mm external width\u003c\/li\u003e\n\u003cli\u003e1110mm internal diameter\u003c\/li\u003e\n\u003cli\u003e1390mm overall height\u003c\/li\u003e\n\u003cli\u003e820mm internal height\u003c\/li\u003e\n\u003cli\u003eTwo 600mm round access manholes\u003c\/li\u003e\n\u003cli\u003e200mm manhole riser height\u003c\/li\u003e\n\u003cli\u003e700mm from each end to manhole centre\u003c\/li\u003e\n\u003cli\u003e100mm PVC inlet, outlet and vent sockets\u003c\/li\u003e\n\u003cli\u003e500mm in-ground support base\u003c\/li\u003e\n\u003cli\u003e870mm above-ground support base\u003c\/li\u003e\n\u003cli\u003e60mm support foot height\u003c\/li\u003e\n\u003cli\u003eInlet plumbing to be installed by a licensed plumber\u003c\/li\u003e\n\u003cli\u003eRisers available on request\u003c\/li\u003e\n\u003cli\u003eLid selected separately to suit the installation and load class\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLiquids Handled\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRaw sewage\u003c\/li\u003e\n\u003cli\u003eTrade waste\u003c\/li\u003e\n\u003cli\u003eEffluent\u003c\/li\u003e\n\u003cli\u003eStormwater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCafés\u003c\/li\u003e\n\u003cli\u003eRestaurants\u003c\/li\u003e\n\u003cli\u003eCanteens\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eBars and hotels\u003c\/li\u003e\n\u003cli\u003eCommercial kitchens\u003c\/li\u003e\n\u003cli\u003eFood courts and multi-tenancy food premises\u003c\/li\u003e\n\u003cli\u003eFood business trade waste pre-treatment\u003c\/li\u003e\n\u003cli\u003eAbove ground grease arrestor installations\u003c\/li\u003e\n\u003cli\u003eBelow ground grease arrestor installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eContaminated water arrives through the 100mm PVC inlet.\u003c\/p\u003e\n\u003cp\u003eThe flow slows across the tank's cross-section, allowing separation to take place under gravity.\u003c\/p\u003e\n\u003cp\u003eSludge and solids settle in the base of the unit.\u003c\/p\u003e\n\u003cp\u003eGrease is trapped and floats to the surface, held below the working level.\u003c\/p\u003e\n\u003cp\u003eTreated liquid is discharged from the grease arrestor to sewer through the 100mm PVC outlet.\u003c\/p\u003e\n\u003ch2\u003eInstallation Information\u003c\/h2\u003e\n\u003cp\u003eThe KGT2000 can be installed above ground or below ground. Inlet plumbing is to be installed by a licensed plumber, and risers are available on request.\u003c\/p\u003e\n\u003cp\u003eImportant installation considerations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe water level and outlet pipe must sit 150mm below the inlet.\u003c\/li\u003e\n\u003cli\u003eAllow for the 2600mm external length and 1150mm width when planning the excavation or plant location.\u003c\/li\u003e\n\u003cli\u003eAbove-ground installations use the 870mm support base arrangement.\u003c\/li\u003e\n\u003cli\u003eIn-ground installations use the 500mm support base arrangement.\u003c\/li\u003e\n\u003cli\u003eBoth 600mm manholes must remain accessible for pump-out and inspection.\u003c\/li\u003e\n\u003cli\u003eAccess covers must be selected to match the traffic load passing over them.\u003c\/li\u003e\n\u003cli\u003eThe 100mm PVC vent connection must be carried through to atmosphere.\u003c\/li\u003e\n\u003cli\u003eAll drawing dimensions carry a 10mm tolerance unless otherwise stated.\u003c\/li\u003e\n\u003cli\u003eSizing, trade waste approval and pump-out frequency are set by the local water authority.\u003c\/li\u003e\n\u003cli\u003eFinal sizing and installation should be approved by the relevant hydraulic consultant, engineer, licensed plumber and local authority.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eKGT2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGrease Arrestor \/ Grease Trap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e2000L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eFibre-Reinforced Polymer (FRP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e1390mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Length\u003c\/td\u003e\n\u003ctd\u003e2600mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Length\u003c\/td\u003e\n\u003ctd\u003e2580mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Diameter\u003c\/td\u003e\n\u003ctd\u003e1110mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Height\u003c\/td\u003e\n\u003ctd\u003e820mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManhole\u003c\/td\u003e\n\u003ctd\u003e600mm Round, 2 Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManhole Riser Height\u003c\/td\u003e\n\u003ctd\u003e200mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManhole Setback\u003c\/td\u003e\n\u003ctd\u003e700mm from Each End\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Connection\u003c\/td\u003e\n\u003ctd\u003e100mm PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd\u003e100mm PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Connection\u003c\/td\u003e\n\u003ctd\u003e100mm PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Ground Support Base\u003c\/td\u003e\n\u003ctd\u003e500mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbove-Ground Support Base\u003c\/td\u003e\n\u003ctd\u003e870mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport Foot Height\u003c\/td\u003e\n\u003ctd\u003e60mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eAbove and Below Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparation Method\u003c\/td\u003e\n\u003ctd\u003eGravity Separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparated Materials\u003c\/td\u003e\n\u003ctd\u003eFats, Oils, Grease and Suspended Solids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquids Handled\u003c\/td\u003e\n\u003ctd\u003eRaw Sewage, Trade Waste, Effluent and Stormwater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensional Tolerance\u003c\/td\u003e\n\u003ctd\u003e10mm Unless Otherwise Stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrease Separator Reference\u003c\/td\u003e\n\u003ctd\u003eKGS2000AG \/ KGS2000BG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrawing Reference\u003c\/td\u003e\n\u003ctd\u003eAL19-TS20600-P \/ STS.11.26.2L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAline Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eKwikflo Grease Trap Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eExact dimensions, nominal operating volume, lid selection and riser requirements for the KGT2000 should be confirmed against the current manufacturer's technical drawing before ordering.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Kwikflo KGT2000 2000L FRP Grease Arrestor Tank\u003c\/li\u003e\n\u003cli\u003e1 x Aline Poly Lid 450mm to Suit\u003c\/li\u003e\n\u003cli\u003e1 x Aline Foam Tape\u003c\/li\u003e\n\u003cli\u003e2 x 600mm Round Access Manholes\u003c\/li\u003e\n\u003cli\u003e1 x 100mm PVC Inlet Connection\u003c\/li\u003e\n\u003cli\u003e1 x 100mm PVC Outlet Connection\u003c\/li\u003e\n\u003cli\u003e1 x 100mm PVC Vent Connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRisers and inlet plumbing are selected and supplied separately to suit the installation. A Class D lid configuration is available for below-ground trafficable installations. Contact our team to specify the correct lid and riser arrangement for your site.\u003c\/p\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kwikflo-kgt2000-2000l-grease-arrestor-brochure_0526936b-f610-4d3f-ba07-75b2bbd05903.pdf?v=1784434423\"\u003eProduct Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNeed Assistance or Ready to Order?\u003c\/h2\u003e\n\u003cp\u003eOur expert team is here to help you select the perfect setup and answer any questions. Contact us at sales@waternex.com.au or give us a call at 1300 930 847 for personalized advice and support.\u003c\/p\u003e","brand":"Kwikflow","offers":[{"title":"Default Title","offer_id":55349628404003,"sku":"KGT2000","price":5399.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kgt2000-render.png?v=1784434434","url":"https:\/\/waternex.com.au\/products\/kwikflo-kgt2000-2000l-grease-trap-arrestor-fibreglass-frp-tank","provider":"Waternex Australia","version":"1.0","type":"link"}