{"product_id":"kwikflo-kus-series-undersink-pump-station-poly-stainless-steel","title":"Kwikflo KUS Series Undersink Pump Station - Poly \u0026 Stainless Steel","description":"\u003cp\u003eThe Kwikflo KUS Series Undersink Pump Station is a pre-assembled greywater lifting station for sinks, basins and appliances below the sewer line. Available in a 40L polyethylene tank or 40L and 80L 304 stainless steel, each comes fitted with a submersible pump, in-tank valves and pipework. The vented, odour-sealed stainless models suit hygiene-sensitive commercial sites – cafes, kitchens, dental surgeries and laboratories.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePre-assembled undersink packaged pump station\u003c\/li\u003e\n\u003cli\u003ePoly (40L) or 304 stainless steel (40L, 80L)\u003c\/li\u003e\n\u003cli\u003eLifts greywater, sink waste, trade waste, effluent and stormwater\u003c\/li\u003e\n\u003cli\u003eMaximum head 7 or 11m depending on pump selected\u003c\/li\u003e\n\u003cli\u003eVortex, high-head or drainage pump options\u003c\/li\u003e\n\u003cli\u003eOdour eliminated by vent and compressible gasket\u003c\/li\u003e\n\u003cli\u003ePVC ball and non-return valves and barrel unions pre-fitted\u003c\/li\u003e\n\u003cli\u003eHigh-level alarm option\u003c\/li\u003e\n\u003cli\u003eHeavy-duty 304 stainless construction on SS models\u003c\/li\u003e\n\u003cli\u003eSuits cafes, kitchens, dental surgeries and laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Kwikflo KUS Series undersink pump station features and specifications\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kus-feature.png?v=1784599197\"\u003e\u003c\/p\u003e\n\u003ch2\u003eGreywater Lifting for Commercial Fixtures\u003c\/h2\u003e\n\u003cp\u003eWhere a sink, basin or appliance sits below the sewer line, the KUS collects the greywater in its tank and pumps it up to the drain. The stainless steel models are built for hygiene-sensitive settings – dental surgeries, laboratories, cafes and commercial kitchens – where a wipe-clean, corrosion-resistant tank matters.\u003c\/p\u003e\n\u003ch2\u003ePoly or Stainless, 40L or 80L\u003c\/h2\u003e\n\u003cp\u003eThe KUSP40 uses a 40L polyethylene tank – the value option for lighter-duty greywater. The KUS40 and KUS80 step up to 304 stainless steel at 40L and 80L, adding capacity and a heavy-duty, hygienic build. All three are pre-plumbed with valves and pipework and require venting.\u003c\/p\u003e\n\u003ch2\u003eSealed Against Odour\u003c\/h2\u003e\n\u003cp\u003eA vent and compressible gasket seal the tank so odour is contained – important for an undersink unit installed inside a cabinet in a food or clinical space. A high-level alarm can be added to warn of a rising level before it becomes a problem.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePre-assembled undersink pump station\u003c\/li\u003e\n\u003cli\u003e40L poly, or 40L \/ 80L 304 stainless steel\u003c\/li\u003e\n\u003cli\u003eSubmersible pump – vortex, high-head or drainage type\u003c\/li\u003e\n\u003cli\u003eMaximum head 7 or 11m (pump-dependent)\u003c\/li\u003e\n\u003cli\u003ePVC ball and non-return valves, barrel unions\u003c\/li\u003e\n\u003cli\u003ePVC interconnecting pipework\u003c\/li\u003e\n\u003cli\u003eVent and compressible gasket for odour control\u003c\/li\u003e\n\u003cli\u003eHigh-level alarm option\u003c\/li\u003e\n\u003cli\u003eRequires venting\u003c\/li\u003e\n\u003cli\u003eHeavy-duty stainless models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLiquids Handled\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGreywater\u003c\/li\u003e\n\u003cli\u003eSink waste\u003c\/li\u003e\n\u003cli\u003eTrade waste\u003c\/li\u003e\n\u003cli\u003eEffluent\u003c\/li\u003e\n\u003cli\u003eStormwater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCafes and commercial kitchens\u003c\/li\u003e\n\u003cli\u003eHobby rooms\u003c\/li\u003e\n\u003cli\u003eDental surgeries\u003c\/li\u003e\n\u003cli\u003eLaboratories\u003c\/li\u003e\n\u003cli\u003eBasement and lower-floor sinks below sewer\u003c\/li\u003e\n\u003cli\u003eHygiene-sensitive greywater lifting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eKUSP40\u003c\/th\u003e\n\u003cth\u003eKUS40\u003c\/th\u003e\n\u003cth\u003eKUS80\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene\u003c\/td\u003e\n\u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Volume\u003c\/td\u003e\n\u003ctd\u003e40L\u003c\/td\u003e\n\u003ctd\u003e40L\u003c\/td\u003e\n\u003ctd\u003e80L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (D x W x H)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e400 x 500 x 450mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. Weight\u003c\/td\u003e\n\u003ctd\u003e~12kg*\u003c\/td\u003e\n\u003ctd\u003e~22kg*\u003c\/td\u003e\n\u003ctd\u003e33kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Head\u003c\/td\u003e\n\u003ctd\u003e7 or 11m\u003c\/td\u003e\n\u003ctd\u003e7 or 11m\u003c\/td\u003e\n\u003ctd\u003e7 or 11m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Type\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eVortex, High-Head or Drainage (as specified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValves\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003ePVC Ball and Non-Return, Barrel Unions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOdour Control\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eVent and Compressible Gasket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eHigh-Level Alarm Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eRequired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eAline Pumps (Kwikflo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*40L weights are estimates pending confirmation against Aline's technical data. The 80L stainless weight (33kg) is from the manufacturer datasheet.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cp\u003eEvery KUS station ships pre-assembled:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Kwikflo KUS Undersink Tank (material and capacity per model below)\u003c\/li\u003e\n\u003cli\u003e1 x Submersible Pump, factory-fitted (vortex, high-head or drainage as specified)\u003c\/li\u003e\n\u003cli\u003e1 x Set of PVC Ball and Non-Return Valves with Barrel Unions\u003c\/li\u003e\n\u003cli\u003e1 x PVC Interconnecting Pipework\u003c\/li\u003e\n\u003cli\u003e1 x Float Switch\u003c\/li\u003e\n\u003cli\u003e1 x Sealed Lid with Compressible Gasket\u003c\/li\u003e\n\u003cli\u003e1 x Installation Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhat changes between models:\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eTank Material\u003c\/th\u003e\n\u003cth\u003eCapacity\u003c\/th\u003e\n\u003cth\u003eDimensions (D x W x H)\u003c\/th\u003e\n\u003cth\u003eApprox. Weight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKUSP40\u003c\/td\u003e\n\u003ctd\u003ePolyethylene\u003c\/td\u003e\n\u003ctd\u003e40L\u003c\/td\u003e\n\u003ctd\u003eConfirm with Aline\u003c\/td\u003e\n\u003ctd\u003e~12kg*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKUS40\u003c\/td\u003e\n\u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003ctd\u003e40L\u003c\/td\u003e\n\u003ctd\u003eConfirm with Aline\u003c\/td\u003e\n\u003ctd\u003e~22kg*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKUS80\u003c\/td\u003e\n\u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003ctd\u003e80L\u003c\/td\u003e\n\u003ctd\u003e400 x 500 x 450mm\u003c\/td\u003e\n\u003ctd\u003e33kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*40L weights are estimates pending confirmation against Aline's technical data. The KUS80 figure (33kg) is from the manufacturer datasheet. All models share the same maximum head of 7 or 11m depending on the pump selected, and all require venting.\u003c\/p\u003e\n\u003cp\u003eA high-level alarm can be supplied separately. Vent line and inlet connections are installed by the plumber.\u003c\/p\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kwikflo-kus80-undersink-datasheet.pdf?v=1784599189\"\u003eKUS80 Product Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNeed Assistance or Ready to Order?\u003c\/h2\u003e\n\u003cp\u003eOur expert team is here to help you select the perfect setup and answer any questions. Contact us at sales@waternex.com.au or give us a call at 1300 930 847 for personalized advice and support.\u003c\/p\u003e","brand":"Kwikflow","offers":[{"title":"KUSP40 - 40L Polyethylene","offer_id":55355819098403,"sku":"KUSP40","price":1952.28,"currency_code":"AUD","in_stock":true},{"title":"KUS40 - 40L Stainless Steel","offer_id":55355819131171,"sku":"KUS40","price":2018.28,"currency_code":"AUD","in_stock":true},{"title":"KUS80 - 80L Stainless Steel","offer_id":55355819163939,"sku":"KUS80","price":2230.8,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0816\/5621\/7891\/files\/kus80-render.png?v=1784599194","url":"https:\/\/waternex.com.au\/products\/kwikflo-kus-series-undersink-pump-station-poly-stainless-steel","provider":"Waternex Australia","version":"1.0","type":"link"}